Inverter on-grid 1 or 3 phase 10kW 48V MPPT 15kWp
Main Features
- Pure sine wave output
- Self-consumption and Feed-in to the grid
- Programmable supply priority for PV, Battery or Grid
- User-adjustable battery charging current suits different types of batteries
- Programmable multiple operation modes: Grid-tie, off-grid and grid-tie with backup
- Built-in timer for various mode of on/off operation
- Multiple communication for USB, RS-232, Modbus and SNMP
- Monitoring software for real-time status display and control
- Parallel operation up to 6 units for 5KW and 10KW
Model InfiniSolar 10KW
PHASE 3-phase in / 3-phase out
RATED OUTPUT POWER 10000 W
MAXIMUM CHARGING POWER 9600 W
GRID-TIE OPERATION
PV INPUT (DC)
Maximum DC Power 14850W
Nominal DC Voltage / Maximum DC Voltage 720 VDC / 900 VDC
Start-up Voltage / Initial Feeding Voltage 320 VDC / 350 VDC
MPP Voltage Range 350 VDC ~ 850 VDC
Number of MPP Trackers / Maximum Input Current 2 / 2 x 18.6A
GRID OUTPUT (AC)
Nominal Output Voltage 230 VAC (P-N) / 400 VAC (P-P)
Output Voltage Range 184 – 265 VAC per phase
Nominal Output Current 14.5A per phase
Power Factor > 0.99
EFFICIENCY
Maximum Conversion Efficiency (DC/AC) > 96%
European Efficiency@ Vnominal > 95%
OFF-GRID OPERATION
AC INPUT
AC Start-up Voltage/Auto Restart Voltage 120 – 140 VAC per phase / 180 VAC per phase
Acceptable Input Voltage Range 170 – 280 VAC per phase
Number of MPP Trackers / Maximum Input Current 25A
PV INPUT (DC)
Maximum DC Voltage 900 VDC
MPP Voltage Range 350 VDC ~ 850 VDC
Maximum Input Current 2 / 2 x 18.6A
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage 230 VAC (P-N) / 400 VAC (P-P)
Output Waveform Pure Sinewave
Efficiency (DC to AC) 91%
HYBRID OPERATION
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage 720 VDC / 900 VDC
Start-up Voltage / Initial Feeding Voltage 320 VDC / 350 VDC
MPP Voltage Range 350 VDC ~ 850 VDC
Maximum Input Current 2 / 2 x 18.6A
GRID OUTPUT (AC)
Nominal Output Voltage 230 VAC (P-N) / 400 VAC (P-P)
Output Voltage Range 184 – 265 VAC per phase
Nominal Output Current 14.5A per phase
AC INPUT
AC Start-up Voltage/Auto Restart Voltage 120 – 140 VAC per phase / 180 VAC per phase
Acceptable Input Voltage Range 170 – 280 VAC per phase
Maximum AC Input Current 25A
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage 230 VAC (P-N) / 400 VAC (P-P)
Efficiency (DC to AC) 91%
BATTERY & CHARGER
Nominal DC Voltage 48 VDC
Maximum Charging Current Default 60A, 5A – 200A (Adjustable)
GENERAL
PHYSICAL
Dimension, D x W x H (mm) 622 x 500 x 167.5
Net Weight (kgs) 45
INTERFACE
Communication Port RS-232/USB and CAN Interface
Intelligent Slot Optional SNMP, Modbus, and AS-400 cards available
ENVIRONMENT
Humidity 0 ~ 90% RH (No condensing)
Operating Temperature -10 to 55°C
Altitude 0 ~ 1000 m*